GUMBOS matrices of variable hydrophobicity for matrix-assisted laser desorption/ionization mass spectrometry

Show simple item record

dc.contributor.author Ghafly, Hashim Al
dc.contributor.author Siraj, Noureen
dc.contributor.author Das, Susmita
dc.contributor.author Regmi, Bishnu P.
dc.contributor.author Magut, Paul Sang
dc.contributor.author Indika, Waduge
dc.contributor.author Murray, Kermit K.
dc.contributor.author Warner, Isiah M.
dc.date.accessioned 2022-11-22T08:40:37Z
dc.date.available 2022-11-22T08:40:37Z
dc.date.issued 2014-08-24
dc.identifier.uri 10.1002/rcm.7027
dc.identifier.uri http://repository.dkut.ac.ke:8080/xmlui/handle/123456789/7739
dc.description.abstract RATIONALE: Detection of hydrophobic peptides remains a major obstacle for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). This stems from the fact that most matrices for MALDI are hydrophilic and therefore have low affinities for hydrophobic peptides. Herein, 1-aminopyrene (AP) and AP-derived group of uniform materials based on organic salts (GUMBOS) as novel matrices for MALDI-MS analyses of peptides were investigated for hydrophobic and hydrophilic peptides. METHODS: A number of solid-phase AP-based GUMBOS are synthesized with variable hydrophobicity simply by changing the counterions. Structures were confirmed by use of H NMR and electrospray ionization mass spectrometry (ESI-MS). 1-Octanol/water partition coefficients (Ko/w) were used to measure the hydrophobicity of the matrices. A dried-droplet method was used for sample preparation. All spectra were obtained using a MALDI-TOF mass spectrometer in positive ion reflectron mode. 1 RESULTS: A series of AP-based GUMBOS was synthesized including [AP][chloride] ([AP][Cl]), [AP][ascorbate] ([AP][Asc]) and [AP][bis(trifluoromethane)sulfonimide] ([AP][NTf2]). The relative hydrophobicities of these compounds and α-cyano4-hydroxycinnamic acid (CHCA, a common MALDI matrix) indicated that AP-based GUMBOS can be tuned to be much more hydrophobic than CHCA. A clear trend is observed between the signal intensities of hydrophobic peptides and hydrophobicity of the matrix. CONCLUSIONS: MALDI matrices of GUMBOS with tunable hydrophobicities are easily obtained simply by varying the counterion. We have found that hydrophobic matrix materials are very effective for MALDI determination of hydrophobic peptides and, similarly, the more hydrophilic peptides displayed greater intensity in the more hydrophilic matrix. en_US
dc.language.iso en en_US
dc.publisher Wiley Online Library en_US
dc.title GUMBOS matrices of variable hydrophobicity for matrix-assisted laser desorption/ionization mass spectrometry en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account